Periodic Maintenance
General Information
NOTE
• This section includes additional
Dangerous Voltage
procedures that are not in the
Operator Manual, Publication
• Disconnect the main power before
No. 981158.
lubricating the parts.
• To provide for optimum operation of the
• Do not allow any oil or grease to touch the
processor, it is important to use the
CROSSOVERS and RACK ASSEMBLIES or
following procedures.
to drip into the TANKS.
[1] Process 5 sheets of unprocessed film before
[4] Provide lubrication if necessary.
you begin the periodic maintenance. Check
[5] Use the correct procedure to clean parts.
for artifacts.
[6] Make the necessary adjustments.
[2] Check for:
[7] Process 5 sheets of unprocessed film in the
• cleanliness
processor after you have performed any
• broken parts
service. Check for artifacts.
• wear of parts
• leakage
• site specifications
[3] Install new parts for the broken parts and
parts that have wear.
Lubrication Table
Part Lubricant Frequency Procedure
Main Drive Chain NLGI - No. 2 Lithium Ball As necessary. Apply to surface of
and Roller Bearing Check each month. Chain.
Grease, TL-2324
Recirculation Pumps Light oil, such as SAE Every 6 months. Several drops in the oil
No. 20 Motor Oil, holes.
TL-2244
Main Drive Motor No lubrication necessary -- --
Gear Housing of the No lubrication necessary -- --
Main Drive Motor
Dryer Blower Motor Light oil, such as SAE Every 6 months. Several drops in the oil
Bearings No. 20 Motor Oil, holes.
TL-2244
981777 3-1