Periodic Maintenance
General Information
NOTE
This section includes additional
Dangerous Voltage
procedures that are not in the
Operator Manual, Publication
Disconnect the main power before
No. 981158.
lubricating the parts.
To provide for optimum operation of the
Do not allow any oil or grease to touch the
processor, it is important to use the
CROSSOVERS and RACK ASSEMBLIES or
following procedures.
to drip into the TANKS.
[1] Process 5 sheets of unprocessed film before
[4] Provide lubrication if necessary.
you begin the periodic maintenance. Check
[5] Use the correct procedure to clean parts.
for artifacts.
[6] Make the necessary adjustments.
[2] Check for:
[7] Process 5 sheets of unprocessed film in the
cleanliness
processor after you have performed any
broken parts
service. Check for artifacts.
wear of parts
leakage
site specifications
[3] Install new parts for the broken parts and
parts that have wear.
Lubrication Table
Part Lubricant Frequency Procedure
Main Drive Chain NLGI - No. 2 Lithium Ball As necessary. Apply to surface of
and Roller Bearing Check each month. Chain.
Grease, TL-2324
Recirculation Pumps Light oil, such as SAE Every 6 months. Several drops in the oil
No. 20 Motor Oil, holes.
TL-2244
Main Drive Motor No lubrication necessary -- --
Gear Housing of the No lubrication necessary -- --
Main Drive Motor
Dryer Blower Motor Light oil, such as SAE Every 6 months. Several drops in the oil
Bearings No. 20 Motor Oil, holes.
TL-2244
981777 3-1