Adjustment of the Replenishment Pumps
[1] Remove the TOP COVER and the
RECEIVING BIN.
[2] Loosen the 2 SCREWS and remove the
PUMP COVER.
[3] Actuate the DETECTOR SWITCH, by lifting
the top DETECTOR ROLLER of the
DETECTOR CROSSOVER ASSEMBLY, until
the ADJUSTMENT SCREW is visible through
the hole in the BRACKET.
[4] Loosen the SETSCREW.
Do not adjust the LOCKNUT on the
H112_0115AC
H112_0115ACC
BRACKET
SCREW (2)
PUMP COVER
TOP COVER
other end of the ADJUSTMENT
SCREW.
[5] Rotate the ADJUSTMENT SCREW: [7] Check the flow rates and do steps 2 - 6 again
if necessary. See the table on page 2-41 for
various replenishment rates.
clockwise to increase the flow
[8] Install the TOP COVER, the PUMP COVER,
rate
and the RECEIVING BIN.
counterclockwise to decrease the flow
[9] Check that the REPLENISHMENT PUMPS
rate
operate correctly by feeding a sheet of film
into the processor. See page 2-4.
[6] Tighten the SETSCREW.
H112_0030BC
DECREASE INCREASE
OUTPUT
ADJUSTMENT SCREW
HOLE
BRACKET
REPLENISHMENT PUMP
LOCKNUT
adjust!
Do not
SCREW
ADJUSTMENT
SETSCREW
H112_0030BCB
Adjustment of the Replenishment Pumps
981777 2-37