EasyManua.ls Logo

Kodak M35 - Rack Assemblies

Kodak M35
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rack Assemblies
When you remove the FIXER RACK
ASSEMBLY, install a SPLASH GUARD
between the DEVELOPER TANK and
the FIXER TANK to prevent
contamination of the developer. Use a
DRIP TRAY when you remove the
RACK ASSEMBLIES. Install the
RACK ASSEMBLIES slowly into the
TANKS.
Rollers
[1] Remove the RACK ASSEMBLIES from the
H112_0015AC
DRIP TRAY
SPLASH GUARD
H112_0015ACA
processor.
[2] Rinse the RACK ASSEMBLIES with warm
water, approximately 44°C (110°F).
NOTE
Discoloration of the ROLLERS is normal.
[3] If necessary, use a soft brush or:
Developer Rack
Kodak
Liquid Developer
Assembly System Cleaner
.
Fixer Rack Assembly
Kodak
Fixer/Wash
System Cleaner
Wash Rack Assembly
smooth, flat surface
H112_0110AA
[4] Remove the STUDS from the drive side.
[5] Remove all the OUTER ROLLERS on the entrance side except the bottom OUTER ROLLER.
[6] Clean the INNER and OUTER ROLLERS.
[7] Check all SPROCKETS and GEARS for wear.
[8] Check that all ROLLERS are straight.
[9] Install the ROLLERS in the RACK ASSEMBLY.
[10] Check:
That the ROLLERS are installed correctly.
The REWET ROLLER for wear.
That the REWET ROLLER is smooth.
That the REWET ROLLER touches the ROLLERS above and below it.
The RACK ASSEMBLY for squareness. See page 2-7.
981777 3-5