COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S131
9Y3200007CRS0166US0
Name CAN2 frame error
ISO 14229
P-Code
U0084 U0086
J1939-73
SPN 523593 523595
FMI 22
SPN Name
SAE J1939 Table
C1
proprietary proprietary
DTC Name CAN DDC1 (Transmission) frame error CAN ETC5 (Neutral SW) frame error
Detection item • CAN_DDC1 communication stopping • CAN_ETC5 communication stopping
DTC Set
Preconditions
• Battery voltage is normal
• Starter Switch signal (Engine ECU: V12
terminal) is not activated
• Battery voltage is normal
• Starter Switch signal (Engine ECU: V12
terminal) is not activated
DTC set parameter • CAN DDC1 frame time out error • CAN ETC5 frame time out error
Time to action or
number of error
detection
• 0.5 sec. or more • 0.5 sec. or more
Limp Home Action
by engine ECU
(system action)
• Accelerator non-linear processing flag =
0 [default value]
• Accelerator non-linear processing invalid
• Neutral SW = OFF [default value]
Behaviour During
Malfunction
•None •None
Engine Warning
Light
•ON •ON
Recovery from
error
• Key switch turn OFF • Key switch turn OFF
Delay time for
recovery
––
Remark