Commissioning
Handling the memory module
6
l
124
EDS84DG752 EN 7.0
4...7.5kW
E84DG127
0 Memory module, pluggable
) Note!
ƒ When the device is switched on, all parameters are automatically loaded
from the memory module to the main memory of the inverter.
– If DIP1/1 is in the ON position, the inverter works with the settings made
via DIP1 and DIP2 and shows these settings in the corresponding codes.
ƒ The 8400 BaseLine and 8400 motec inverters use the same (grey) memory
module. The memory module can be shifted between these inverters,
however, the corresponding inverter must be reparameterised afterwards.
When handling the memory module, a distinction is drawn between the following
scenarios:
Delivery status
ƒ The memory module is plugged into the EPM slot of the drive unit.
ƒ The Lenze setting of the parameters is stored in the memory module.
ƒ The memory module is available as a spare part ˘ without any data contents˘.
During operation
Parameter sets can be saved manually.
ƒ Parameter sets can be loaded manually.
ƒ Parameter changes can be saved automatically.