Commissioning
Commissioning via DIP switch/potentiometer
Before switching on
6
l
135
EDS84DG752 EN 7.0
6.3.3 Before switching on
ƒ The wiring unit is mounted and wired as described in the instructions,
directly on a motor clamping flange or
with the wall adapter on a suitable surface near the motor.
ƒ Connections with the mains, motor, holding brakes, etc. have been established.
ƒ The communication unit has been mounted and wired according to the scheduled
application.
Input and output signals
Safe input
Fieldbus
(depending on the version, only optionally available)
ƒ If required, the basic settings for "local mode" have been carried out.
DIP switch
Potentiometer
ƒ The drive unit has been mounted and screwed together.
ƒ Use available control functions reasonably, e.g.
Inhibit controller enable
Set speed adjustment to the minimum setting
Activate safety system
ƒ The use of a brake resistor has been checked.
In the case of dynamic loads or difficult control conditions, the use of the internal
E84DZEW47R0001 brake resistor is always recommended for devices
E84DGDVB4024 ... 7524 (4...7.5 kW).
} Danger!
Great hazard potential during commissioning
Incorrect settings may cause unexpected and dangerous motor and system
movements.
Possible consequences:
ƒ Damage to material assets
ƒ Injury to persons
Protective measures:
ƒ Clear hazardous area
ƒ Observe safety instructions and safety clearances