Technical data
Control terminals
EtherNet/IP
4
l
65
EDS84DG752 EN 7.0
4.7.6 EtherNet/IP
Feature Value/designation
Communication
Communication profile EtherNET/IP, AC Drive
Medium CAT5e S/FTP in compliance with ISO/IEC11801 / EN50173
Baud rate b 10/100Mbps (full duplex/half duplex)
Network topology Tree, star, line
Nodes Slave (adapter)
Number of nodes Max. 254 in the subnetwork
Number of logic process data channels 1
Process data words (PCD)
16bit 1...16
Max. cable length
Between two nodes l
max
100m
Rated voltage U
rated
,
DC
24.0V
4.7.7 PROFIBUS®
Feature Value/designation
Communication
Communication profile PROFIBUS−DP−V0 (DRIVECOM)
PROFIBUS−DP−V1 (PROFIdrive)
Medium RS485
Baud rate b 9.6...12000kbps (automatic detection)
Network topology With repeater: line or tree
Without repeater: line
Nodes Slave
Number of nodes 31 slaves + 1 master per bus segment
With repeater: 125
DP user data length Optional parameter channel (4 words) + process data words
Acyclic parameter data channel (DP−V1): max 240bytes
Process data words (PCD)
16bit 1...8
Max. cable length
Per bus segment l
max
1200m (depending on the cable type used and the baud rate)
Rated voltage U
rated
,
DC
24.0V