Installation
Control terminals
AS−Interface STO
5
l
99
EDS84DG752 EN 7.0
5.9.5 AS−Interface STO
Terminals
Mode Features Position of M12 plug
AS−Interface STO
E84DGFCAFJP
Controller enable RFR 1
A1
A2
A3
A4
LED
Bus
DI1/DI2
B4
B3
B2
B1
Digital inputs DIx 5
Digital outputs DOx 1
Analog inputs AU/AI 1
Relay NO 1
STO safety function STO 1
External 24 V supply 24E ˘
E84DG126c
Mode Features Position of M12 plug
AS−Interface STO
Enhanced
E84DGFCAEJP
Controller enable RFR 1
A1
A2
A3
A4
LED
Bus
DI1/DI2
Safety
NO/DO1
AU/AI
B4
B3
B2
B1
Digital inputs DIx 5
Digital outputs DOx 1
Analog inputs AU/AI 1
Relay NO 1
STO safety function STO 1
External 24 V supply 24E ˘
E84DG126d
DC 24 V
(+19.2 … +28.8 V)
+
-
SAFETY
X61
SIB
GI
SIA
DO
24O
S1
24 V
ext.
+
-
2k ... 10k
0 ... 10 V / 0/4 ... 20 mA
1)
3.3k
3.3k
3.3k
3.3k
3.3k
3.3k
+10 V/
5 mA
DI1
DI2
DI3
DI4
DI5
DO1
RFR
X4
GND
AU/AI
AR
COM
NO
n. c.
n. c.
24 V int.
100 mA
24O
24O
GND
GND
X3
AS-i +
AS-i -
n. c.
E84DG015c
1)
External alternative voltage supply
2)
Wire jumper for permanent controller enable (delivery state)
Assignment of M12 plug
A2 Assignment
2
4
5
3
1
1 ASI IN
2 n.c.
3 ASI OUT
M12 male socket
A−coding
4 n.c.
5 n.c.