Technical data
Control terminals
AS−Interface
4
l
63
EDS84DG752 EN 7.0
Standards and application conditions
Feature Value/designation
Type of protection
EN60529 IP65
Climatic conditions
Storage (EN60721−3−1) 1K3 (temperature: −30°C...+60°C)
Operation (EN60721−3−3) 3K3 (temperature: −30°C...+55°C)
Transport (EN60721−3−2) 2K3 (temperature: −30°C...+75°C)
Insulation voltage to PE reference earth
EN61800−5−1 U
AC
50.0V
Safety system
Feature Value/designation
Communication module AS−Interface STO, CANopen STO, EtherCAT® STO, EtherNet/IP STO,
PROFIBUS STO, PROFINET STO
Certification
ENISO13849−1 PLe, category 4
EN61800−5−2 SIL3
EN62061 SIL3
IEC61508 SIL3
Fail−safe state Safe torque off
4.7.3 AS−Interface
Feature Value/designation
Standard EN50295 / IEC62026−2
Communication
Communication profile AS−Interface V3.0
Medium Two−core cable for data and auxiliary power
Network topology Free topology (line, ring, tree, star)
Nodes
Slave (single, dual)
Max. 31 standard slaves or safe slaves
Max. 62 A/B slaves
Number of nodes 1... 31
Max. cable length
Per bus segment l
max
100m without repeater/extender
300m with 2 repeaters/extenders
500m only in star topologies with 2 repeaters/extenders
Baud rate
167kbps (gross)
53kbps (net with data transmission efficiency = 32%)
Rated voltage U
rated
,
DC
24.0V