Commissioning
Commissioning via DIP switch/potentiometer
Commissioning steps
6
l
 136
EDS84DG752  EN  7.0
6.3.4 Commissioning steps
Proceed step by step:
ƒ Switch on the mains
ƒ Monitor status display
– After a short initialisation time, the display must be blinking green.
ƒ Deactivate requirements of the safety function
ƒ Set controller enable
– After the set starting time, the motor must rotate with the speed set.
ƒ Initial check of the expected behaviour:
– Direction of rotation?
– Starting time?
– Speed?
– Speed control?
ƒ Check of optional control functions:
– Is the analog setpoint selection working?
– Are the digital control signals, e.g. limit switches, working?
– Is the connected motor holding brake working?
– Is the function for changing over the rotating direction working?
– Is the requirement with regard to the safety function working?
– Are the control signals via fieldbus working?
ƒ Switch off drive
– Reduce speed
– Inhibit controller enable
– Switch off mains
) Note!
Save parameter settings safe against mains failure
In order to prevent parameter settings carried out in the device from being lost
by mains switching, you have to explicitly save the parameter set with mains
failure protection in the device.