Product description
Product key
Field Package without switch
3
l
27
EDS84DG752 EN 7.0
3.4.6 Field Package without switch
Z2 5 x x 0 x x x x x x F
Product variant
Field Package without switch − 8400 motec
Version
5 = not relevant
Connection technique for power terminal
A = cable gland
B = 2 x Q4/2, Q8/0
C = Quickon, Q8/0
Connection technique for DC 24 V
0 = without
A = cable gland
B = Q4/2
Brake resistor
0 = without
A = 220 Ohm integrated
B = 90 Ohm integrated
Fieldbus
0 = without
A = AS−Interface
C = CANopen
T = EtherCAT®
G = EtherNet/IP
P = PROFIBUS
R = PROFINET
I/O terminals
A = BasicI/O (without fieldbus)
B = StandardI/O (without fieldbus) or fieldbus with STO
C = fieldbus without STO
D = ExtendedI/O (without fieldbus)
Drive−based safety
0 = without STO
A = with STO
Connection technique for I/O modules/fieldbus
A = without
C = M12: LED, bus, DI1, DI2
D = M12: LED, bus, DI1, DI2, DO1, NO, AI, STO
E = M12: bus−in, bus−out, DI1, DI2
F = M12: bus−in, bus−out, DI1, DI2 DO1, NO, AI, STO
G = M12: LED, bus−in, bus−out, DI1, DI2
H = M12: LED, bus−in, bus−out, DI1, DI2 DO1, NO, AI, STO
I = M12: LED, bus, DI1, DI2, DI3, DO1
J = M12: bus−in, bus−out, DI1, DI2, DI3, DO1
K = M12: LED, bus−in, bus−out, DI1, DI2, DI3, DO1
Rated power
215 = 10
2
× 15 W = 1.5 kW (example)
Rated voltage
F = 400/480 V, 3/PE AC (also for IT systems)