Commissioning
Commissioning via DIP switch/potentiometer
DIP switch / potentiometer assignment 1
6
l
131
EDS84DG752 EN 7.0
6.3.2 DIP switch / potentiometer assignment 1
(from software version 07.00.00 onwards)
Settings with DIP1
(Lenze setting bold)
DIP1 Switch
Description 1 2 3 4 5 6 7 8
DIP1, DIP2, P1, P2,
P3
Active
ON
Inactive
OFF
Motor power
Motor power > inverter power
ON
Motor power = inverter power
OFF
Control
VFCplus ECO
ON
VFCplus linear
OFF
Brake control /
restart on the fly
Brake control off, restart on the fly off
OFF OFF
Brake control off, restart on the fly on
ON OFF
Brake control automatically
horizontally, restart on the fly off
OFF ON
Brake control automatically
vertically, restart on the fly off
ON ON
Motor mounting
direction
Inverted
ON
Not inverted
OFF
Function P1
Preset setpoint3 is always written to
with P1
ON
Preset setpoint3 is written to once at
mains connection with P1
OFF
Load parameters
after mains
connection
Load parameters from memory
module
ON
Load parameters from the Lenze
setting
OFF