Commissioning
Commissioning via DIP switch/potentiometer
DIP switch / potentiometer assignment 0
6
l
130
EDS84DG752 EN 7.0
Settings with P2
(Lenze setting bold)
With P2 you set the motor setpoint speed as a percentage of the rated speed in C00011 in
10 steps (preset speed setpoint). The preset setpoint is only activated if the DI1 input is set
in "Local mode".
P2 Setting
Description 0 1 2 3 4 5 6 7 8 9
Motor speed in percent of the rated speed setting
C00011
[%] 0 11 22 33 44 55 66 77 88 100
Settings with P3
(Lenze setting bold)
Use P3 to set the acceleration and deceleration time of the motor.
P3 Setting
Description 0 1 2 3 4 5 6 7 8 9
Acceleration and deceleration time of the motor
in seconds
[s] 0.1 0.5 1 2 5 10 20 30 60 120
Settings with P1
(Lenze setting bold)
During operation you can use P1 to steplessly set the motor speed as a percentage of the
rated speed in C00011 if no preset speed setpoint P2 is active via DI1.
Remove cap in order to be able to set potentiometer P1.
ƒ Screw cap on again after the setting process, in order to ensure that the degree of
protection of the inverter is provided.
P1 Setting
Description 0 ... 9
Motor speed in percent of the rated speed C00011 [%] 0 ... 100