General data
Feature Value/designation
Analog input, voltage
Value range 0...10V
Value range − Extended I/O only −10...+10V
Resolution 10bits
Input resistance >80kW
Sampling frequency 80Hz (12ms)
Accuracy ±0.1V
Electric strength of external voltage −7...+30V
Analog input, current
Value range, parameterisable
0.6...+20mA (<0.6mA corresponds to 0)
4...+20mA, fail−safe
Resolution 10bits
Input resistance 250W
Input current in the case of an open circuit Display "0" (I<0.6mA)
Sampling frequency 80Hz (12ms)
Typical accuracy ±0.2mA
Electric strength of external voltage −7...+7V
Digital inputs
Switching level PLC (IEC61131−2)
Max. input current 11mA
Digital outputs
Switching level PLC (IEC61131−2)
Max. output current 50mA
Relay
Contact NO contact
Connection
AC250V, 3A
DC24V, 2A...240V, 0.16A
24 V supply
External (24E) DC input voltage: +19.2...+28.8V
For supporting communication when the mains
voltage is disconnected
Internal (24O) DC output voltage, max. 100mA for inputs/outputs
and sensor supply
Interfaces
Extensions Fieldbus via Communication Unit
Safety system 1 safe input for passive/active actuators
Drive interface
Encoder input
– Basic I/O
– Standard I/O
– Extended I/O
– CANopen
– PROFIBUS
– AS−i
Via 2 digital inputs, HTL, 2−track, 7.5kHz
Encoder input
– PROFINET
– EtherNet/IP
– EtherCAT
Via 2 digital inputs, HTL, 2−track, 10kHz