2-110 Service Manual
7002-xxx
294.01 Error code service check
ADF eject jam.
Note: Before starting this service check, make sure the ADF exit sensor (A) cable is installed correctly.
5
ADF exit sensor—electrical
checks
Turn the power off, and reconnect CN9 to the motor driver card.
Measure the voltages in the table below with the sensor in normal
operation (sensor closed) and the sensor open (sensor flag
activated).
If the voltages are incorrect, replace the ADF exit sensor. If this does
not fix the problem, replace the complete ADF assembly. See “ADF
complete assembly removal” on page 4-15.
Note: Whenever the complete ADF assembly is replaced, it is
necessary to perform scanner registration. See “Scanner
registration” on page 4-4.
FRU Action
1 ADF—jammed media Check for any signs of media or other debris that might be present in
the ADF assembly around the exit sensor flag. Remove any media or
debris. If nothing is found, go to step 2.
FRU Action
ADF exit sensor—interrupter type (normally closed)
Connector CN9 (motor driver card)
Pin number Sensor closed Sensor open
CN9—Pin 1 0 V dc 0 V dc
CN9—Pin 2 +1.16 V dc +1.16 V dc
CN9—Pin 3 +5.0 V dc +0.15 V dc
Note: All voltages are approximate values.
A