Repair information 4-83
7002-xxx
3. Snap the bottom fastener of the sensor cover into place in the lower exit guide assembly, and use a small
flat bladed screwdriver to ease the sensor cover into the clips.
4. Replace the screw securing the sensor cover.
Note: Make sure the flag moves properly.
Fuser exit sensor flag and spring removal
1. Remove the fuser exit sensor. See “Fuser exit sensor removal” on page 4-82.
2. Note the position of the spring (A) in relation to the flag (B).
3. Carefully ease the right arm (C) until the fuser exit sensor cover releases the flag and spring.