4-48 Service Manual
7002-xxx
Pickup solenoid assembly removal
1. Remove the two screws (A).
2. Unhook the spring (B).
Note: Two springs attach to the same post. The other spring should be hooked on first, and spring (B)
should be attached on the outside or in front of the other spring.
3. Remove the cable from the cable guide.
4. Disconnect the connector (C), and remove the pickup solenoid assembly.
Scanner control card removal
Illustrations represent models X644e/X646e. Unless there is an indication, the procedure is the same. Differences
are shown side by side.
1. Remove the printer left side cover. See “Printer left side cover removal” on page 4-56.
2. Remove the six screws (A) from the SCC and HDD shield.