3.0 The day-to-day weighing process
3.3 How do I perform a warm-up?
Forbestweighingaccuracy,thehydraulicfluidintheliftcylindersshouldbeatnormaloperatingtemperature.
Thisisachievedbyraisingandloweringtheemptybucket.
TheabovemessagewilldisplayiftheIndicatorhasbeenturnedoffformorethanonehour.Ifyouseetheabove
message,youneedtoraiseandthenlowertheemptybucketpasttheTriggerPointthree(3)times:
1. RaisethebucketpasttheTriggerPoint.
2. LowerthebucketpasttheTriggerPoint.
3. Repeattwomoretimesuntilthemessagedisappears.
Whenthewarm-uphascompleted,the
Total
screenwilldisplay.
3.4 How do I zero the empty bucket?
The Check Zero functionality is only available if selected at installation.
Itisnecessarytoperiodically"zero"thebucketbecausesmallerrorscanoccurduetoabuild-upofmaterialin
thebucket.TheFrictionandAmbientCompensationTechnology(FACT)functionalityisalsoupdatedaspartof
thezeroingprocess.
Ifyouseetheabovemessage,youneedtozerotheemptybucket.Themessagewilldisplay:
n
Every15minutesforthefirsthour,and
n
Every30minutesthereafter(thedefaultperiodis30minutes,butitmaybesetbetween15-180minutesat
yoursite).
IMPORTANT – WhenzeroingtheIndicator,thebucketmustbeemptyandkeptfully-rolledback.
Completethefollowingtozerothebucket:
1. Ensurethattheloaderislevelandthebucketisempty.
2. Raisetheemptybucket.
3.
Press .
Theliftingspeedwilldisplay.
NOTE – IfduringinstallationtheFACTupdatewassettobeskipped,press againtocontinue.
Theupdatemayonlybeskippedasetnumberoftimesbeforeanupdatemustbecompleted.
Loadrite L2180 loader scales | 19