14.0 Appendix A: System specifications
14.0 Appendix A:
System specifications
14.1 Weighing accuracy
Typicalaccuracyiswithin±1%formostbucketloaders.Thismayvarywithdifferentmachinetypes,installation
options,andtheoperatingenvironment.
14.2 Minimal weighing delay
Weighingdelayisminimal,becausetheweighingfunctioniscarriedoutduringanormallift.
14.3 Power requirements
Supply voltage 12Vto32VDC
Supply current
LoadriteIndicator:160mAtypical;350mAmax.
Loadriteprinter:50mAstandby,4Apeak.
Automatic transient
suppression
ExceedsrelevantSAEspecificationsforDCautomotivepowersupply
transients.
14.4 Physical specifications
LCD display Backlit;3.8in(diagonal);QVGA.
Tactile keypad Backlit;Numericandspecialfunctions.
Weight 1.5kg(3.2lb)
Dimensions W145xL240xD110mm
(5.7x9.4x4.3in)
Loadrite L2180 loader scales | 76