16.0 Appendix C: Error Messages
16.13 Lift under range
Theliftpressurewastoolow.Thisindicatesafaultineitherthepressuretransducerorthecablethatconnects
thetransducer.
16.14 Low battery
TheIndicatorinternalbatterypowerislowandmustbereplaced.TheLowBatterymessagewilldisplayanda
long'beep'willsoundatstart-uporwhenexiting
StandbyMode
.ContactyourLoadritedistributortoarrangefor
areplacementbattery.
CAUTION – Ifthismessageisignored,theIndicatorwillenter
LowBatterySafeMode
,duringwhich
allproductnames,datafieldsandloadinghistorywillbedeletedandallconfigurationoptionswillbe
resettothedefaultvalues.Calibrationdataisnotaffected,sotheIndicatormaystillbeusedforaccurate
weighing.
16.15 Need emptying
Thebucketmustbecrowedfullyforwardtoensurethatallproducthasbeenemptied.TheNeed Emptying
messagewillbedisplayedIftheLoadriteWeighingSystemhasnotdetectedthatthebuckethasbeencrowded
fullyforward.
NOTE – ThismessageshouldonlybedisplayedwhenusingaLegalforTradescale.
16.16 No lock
Theinterlockwasnotclosedwhenliftingtheload.Theinterlockmustbeclosed(orthebucketmustbefully
rolledback)whileliftingtheload.Noweightisdisplayedandthereforethereisnoweighttoadd.
16.17 Num Attempts Exceeded
ThismessagedisplaysifthenumberofattemptstoperformacheckzeroisexceededwhenFACTisactivated.
Thenumberofattemptsissetduringinstallation.
16.18 Over target
Addingtheliftedweightwillexceedthetargetvalue.Theliftedweightcanstillbeaddedbypressing .
NOTE – The
Auto-add
functionwillnotautomaticallyaddover-targetweight.
Loadrite L2180 loader scales | 83