16.0 Appendix C: Error Messages
16.19 Overload
Theliftedweightexceedsthefullscale(capacity)setting.Ifthe
OverloadError
issetduringinstallation,
overloadedweightcannotbeadded.
16.20 Pitch too high
Theangleoftheloaderisatanunsafepitch(front/backtilt)whileweighing.Ifthismessageisdisplayed,the
weightcannotbeadded.Thesafepitchangleissetduringinstallation.
NOTE – ThismessageshouldonlybedisplayediftheGroundSlopeCompensationmoduleis
installed.
16.21 Poor lift
Ifaweighingerroriscloseto,butnotgreaterthan,thetolerancelimit,theLoadriteIndicatordisplaysthis
warningmessage.Theweightcanbeaddedasusual.
16.22 Printer disabled
Printfunctionhasbeendisabledatinstallation.
16.23 Printer error
Thereisafaultintheprinter.Checkthattheprinterisonlineandhaspaper.
16.24 Return under range
Thereturnpressurewastoolow.Thisindicatesafaultineitherthepressuretransducerorthecablethat
connectsthetransducer.
16.25 Roll too high
Theangleoftheloaderisatanunsaferoll(left/righttilt)whileweighing.Ifthismessageisdisplayed,theweight
cannotbeadded.Thesaferollangleissetduringinstallation.
NOTE – ThismessageshouldonlybedisplayediftheGroundSlopeCompensationmoduleis
installed.
Loadrite L2180 loader scales | 84