5.0 Product Management
5.1.5 Data Suspend
The
DataSuspend
functionality is only available if selected at installation.
DataSuspendisafeaturethatallowsyoutotemporarilysuspenddatavaluesandsetthemto0(zero).
Whiledataissuspended,theLoadriteWeighingSystemwill:
n
Excludeallsuspendeddatafieldsinprinting
n
Overrideallsuspendeddatafieldswith0indatalogging
n
DisplaytheData Suspend messageinsteadofthedatatitleonthe
Total
screen.
Completethefollowingtosuspendorresumedata:
1.
Press .
The
DataMenu
willdisplay.
2.
SelectData Suspend,thenpress .
The
DataSuspend
screenwilldisplay.
3.
Tosuspenddata,selectOn,thenpress ;Toresumedata,selectOff,thenpress .