Chapter 8. Maintaining Units
140 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
• Choose Monitor >> Enclosure from the main menu in 3DM2. On the
list of enclosures, click the ID number of the enclosure. On the
Enclosure Detail page, identify the drive you want to physically
locate.
2 Check the box in the
Identify column.
The LED on the enclosure begins blinking.
3 When you are finished working with the drive and no longer need to see
the LED, return to this page and uncheck the
Identify box.
To blink the LED for a drive through 3BM
1 On the main 3BM screen,
Tab to Information and press Enter.
2 On the pop-up menu, select Drives and press Enter.
3 On the Drive Information page, use the arrow keys to select the drive you
want to identify.
4 Press
F4.
The LED on the enclosure begins blinking. (Note that this feature is only
available for drives in enclosures.)
5 When you are finished working with the drive and no longer need to see
the LED, return to this page and press
F4 again to halt the blinking.
To blink the LEDs for all drives in a unit
1 Choose
Information >> Unit Information from the main menu in 3DM2.
2 On the Unit Information page, identify the unit you are interested in.
3 Check the box in the
Identify column.
The LEDs for the drives in the selected unit begin blinking.
4 When you no longer need to see the LEDs, return to this page and
uncheck the
Identify box.