Problems and Solutions
www.lsi.com/channel/products 231
commands with FUA (Force Unit Access), flush commands, and a
drive sectors's read, write, and write commands with FUA.
(/cx/px show dpmstat type=ext)
•
Clear Individual Statistic Counters. On a per-port basis, you can clear
specific statistic counters, using these commands:
• /cxpx set dpmstat=clear
• /cxpx set dpmstat=clear type=ra
• /cxpx set dpmstat=clear type=lct
• /cxpx set dpmstat=clear type=ext
Problems and Solutions
This section covers some common problems and solutions. It is organized into
the following sections:
• Enclosure-Related Problems
• An LED is blinking red on an enclosure.
• Hardware Installation Problems
• The 3ware BIOS screen never appears
• Need to boot from a non-3ware device without changing the boot
order
• Software Installation Problems
• The 3ware RAID controller was configured without problems, but the
system does not boot
• A unit shows up as unusable, because of missing drives:
• Problems in 3DM2 and 3BM
• A 3ware RAID controller does not show in the list of controllers
• When booting a system, a drive is not showing up in the startup
screens, in 3BM, or in 3DM2
Enclosure-Related Problems
An LED is blinking red on an enclosure.
A blinking red LED on an enclosure may indicate that there is a “predicted
fault” on the drive in that slot. Actual LED behavior will depend on the
enclosure manufacturer. Refer to the user guide for your enclosure.
Such an error can result from a number of different factors, including a
SMART error, read error, or cable error. The drive has not failed yet, but may
fail soon.