Background Tasks
www.lsi.com/channel/products 153
To verify a unit through 3DM2
1 In 3DM2, choose
Management >> Maintenance.
2In the
Unit Maintenance section of the Maintenance page, select the unit
you want to verify and click
Verify Unit.
3DM2 puts the selected unit in verifying mode.
If Basic Verify is selected on the Scheduling page, the verification process
begins almost immediately. If Advanced Verify is selected, the unit will
not start actively verifying until the next scheduled time.
A
Stop Verify link appears next to the unit on the Maintenance page. If
you need to stop the verify process, use this link. (If initialization starts
because the unit had not previously been initialized, it cannot be halted, so
no
Stop Verify link appears.)
To verify a unit through 3BM
1 At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab to the Maintain Unit button and press Enter.
3 On the pop-up menu, select Verify and press Enter.
Verification of the selected unit starts immediately.
Figure 73. Verifying a Unit

Table of Contents

Other manuals for LSI 3ware 9750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSI 3ware 9750 and is the answer not in the manual?

LSI 3ware 9750 Specifications

General IconGeneral
BrandLSI
Model3ware 9750
CategoryController
LanguageEnglish

Related product manuals