EasyManuals Logo

LSI 3ware 9750 User Manual

LSI 3ware 9750
380 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #253 background imageLoading...
Page #253 background image
Error and Notification Messages
www.lsi.com/channel/products 241
See Also
“About Degraded Units” on page 138
“Rebuilding Units” on page 154
0003 Controller error occurred
Event Type
Error
Cause
The 3ware RAID controller has encountered an internal error.
Action
Please collect log files and contact LSI Customer Support, as a replacement
board may be required. Technical support is reachable at
http://www.lsi.com/channel/ContactUs. For information on collecting logs,
search the LSI KnowledgeBase for keyword 12278 at http://kb.lsi.com.
0004 Rebuild failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete a rebuild operation. This
error can be caused by drive errors on either the source or the destination of
the rebuild. However, because ATA drives can reallocate sectors on write
errors, the rebuild failure is most likely caused by the source drive of the
rebuild detecting a read error.
Action
The default operation of the 3ware RAID controller is to abort a rebuild if an
error is encountered. If you want rebuilds to continue when there is a source
error, you can set a unit policy to Continue on Source Error When Rebuilding
in 3DM2 or CLI.
The consequence of continuing a rebuild when there is a source error is that
there may be corrupt data in your rebuilt unit. In some cases, however, this
may be your only alternative for recovering as much data as possible from a
unit that has become degraded.

Table of Contents

Other manuals for LSI 3ware 9750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSI 3ware 9750 and is the answer not in the manual?

LSI 3ware 9750 Specifications

General IconGeneral
BrandLSI
Model3ware 9750
CategoryController
LanguageEnglish

Related product manuals