Chapter 12. Troubleshooting
254 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
0029 Verify started
Event Type
Information
Cause
The 3ware RAID controller has started verifying the data integrity of a unit.
The verification functions for different RAID levels are as follows:
Single. Verify = Media scan
RAID 0. Verify = Media scan
RAID 1 and 10. Verify = Comparison of mirror sides
RAID 5, 6, and 50. Verify = Comparison of parity data with user data
Action
Allow verify to complete to identify any possible data integrity issues.
See Also
For information on scheduling a verify process, see “Scheduling Background
Tasks” on page 163. For information on verification of a unit, see “About
Verification” on page 149.
002A Verify failed
Event Type
Error
Cause
Verification of a unit has terminated with an error. For each RAID level being
verified, this may mean:
Single. A single drive returned an error, possibly because of a media
defect.
RAID 0. A single drive returned an error, possibly because of a media
defect.
RAID 1 and 10. One side of the mirror does not equal the other side.
RAID 5, 6, and 50. The parity data does not equal the user data.
For any RAID type, the most likely cause of the error is a grown defect in the
drive. For out-of-synchronization mirrors or parity, the error could be caused
by improper shutdown of the unit. This possibility applies to RAID 1, 5, 6, 10,
and 50.

Table of Contents

Other manuals for LSI 3ware 9750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSI 3ware 9750 and is the answer not in the manual?

LSI 3ware 9750 Specifications

General IconGeneral
BrandLSI
Model3ware 9750
CategoryController
LanguageEnglish

Related product manuals