Error and Notification Messages
www.lsi.com/channel/products 275
0059 Battery capacity is below error level
Event Type
Error
Cause
The measured capacity of the battery is below the error level. The Battery
Backup Unit is not ready and is unable to backup the 3ware RAID controller.
Action
Replace the battery pack.
See Also
See the Install Guide for your controller.
005A Battery is present
Event Type
Information
Cause
A battery pack is connected to the 3ware RAID controller.
005B Battery is not present
Event Type
Error
Cause
The battery pack has been removed from the 3ware RAID controller.
Action
Reinstall the battery pack.