Error and Notification Messages
www.lsi.com/channel/products 277
0062 Enclosure removed
Event Type
Warning.
Cause
Applies to 9750 and 9690SA controllers.
An enclosure is no longer accessible to the RAID controller. The likely cause
is that the enclosure has been powered down or that a cable has been
unplugged.
0063 Enclosure added
Event Type
Information.
Cause
Applies to 9750 and 9690SA controllers.
An enclosure is now accessible to the RAID controller. The likely cause is
that an enclosure connected to the controller has been powered up or that a
cable has been plugged in.
0064 Local link up
Event Type
Information.
Cause
Applies to 9750 and 9690SA controllers.
A cable has been plugged in, restoring a link to a controller phy.