Error and Notification Messages
www.lsi.com/channel/products 285
Action
If due to a poor connection, the repair will require specialized skills. Contact
your enclosure manufacturer for more information.
8027 Enclosure temp critical
Event Type
Error.
Cause
Applies to 9750 and 9690SA controllers.
The temperature in the enclosure is dangerously out of the recommended
operating range.
Action
Take immediate steps to correct the temperature problem.
Take steps to lower the enclosure temperature, such as adding fans, clearing
enclosure openings of blockages, and increased ventilation of the operating
environment
Continued operation of the enclosure at high temperatures may lead to data
loss and operational failure.
See your enclosure documentation or contact your enclosure manufacturer to
make sure you are following proper operating procedures.
8028 Enclosure temp unknown
Event Type
Warning.
Cause
Applies to 9750 and 9690SA controllers.
The enclosure is reporting that it is unable to determine the temperature of the
unit. This may be due to a failed or missing sensor.

Table of Contents

Other manuals for LSI 3ware 9750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSI 3ware 9750 and is the answer not in the manual?

LSI 3ware 9750 Specifications

General IconGeneral
BrandLSI
Model3ware 9750
CategoryController
LanguageEnglish

Related product manuals