MERLIN LEGEND Communications System Release 6.1
System Programming Guide
555-661-111
Issue 1
August 1998
Programming Procedures
Page 3-52Lines and Trunks
3
Outmode Signaling for Loop- or
Ground-Start Trunks 3
Use this procedure to identify either touch-tone signaling or rotary-dial signaling
for outgoing calls placed by using the specified loop- or ground-start trunk.
NOTE:NOTE:NOTE:
Since the factory setting is touch-tone, this procedure is not required if your
system has only touch-tone lines/trunks.
Summary: Outmode Signaling for Loop-
or Ground-Start Trunks 3
Programmable by System Manager
Mode Loop-Start: All; Ground-Start: Hybrid/PBX only
Idle Condition Not required
Planning Form Form 2c, System Numbering: Line/Trunk Jacks
Factory Setting Touch-tone
Valid Entries Touch-tone, Rotary
Inspect No
Copy Option Yes
Console Procedure To program a single line/trunk:
/LQHV7UXQNV→77/6'LVF→2XWPRGH→Select entry
mode
→Dial no. of line/trunk→(QWHU or 'HOHWH→
([LW→([LW→([LW
To program a block of lines/trunks:
/LQHV7UXQNV→77/6'LVF→2XW0RGH→Select block of lines/
trunks
→Toggle LED On/Off→(QWHU or 'HOHWH→
([LW→([LW→([LW
PC Procedure To program a single line/trunk:

→→→→Type no. of the line/trunk→

or
→→→
To program a block of lines/trunks:

→→→Select block of lines/trunks→
Toggle letter * On/Off→
or
→→→