EasyManua.ls Logo

Maeda CC1485S-1 - Maintenance Every 4000 Hours; Inspection of Water Pump; Replacement of Accumulator

Maeda CC1485S-1
370 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
280
10.10 MAINTENANCE EVERY 4000 HOURS
Perform this maintenance in tandem with maintenance every 50, 250, 500 and 1000 hours.
[1] INSPECTION OF WATER PUMP
Check the pulleys for play, oil leakage, water leakage and drain hole clogging. If any fault is
found, request us or our sales agency for the dismounting and repair.
[2] REPLACING THE ACCUMULATOR
Replace the accumulator every 2 years or 4000 hours of service, whichever falls first.
Since the accumulator is charged with high pressure nitrogen gas, any incorrect
handling of it may cause an explosion and therefore cause a serious accident. Strictly
observe the following for handling:
The pressure in the hydraulic circuit cannot be totally relieved.
When removing a
hydraulic unit, stay away from the escaping oil direction. Also, loosen screws slowly.
Never disassemble them.
Do not allow fire to come close to them or throw them into a fire.
Do not attempt drilling, or gas cutting.
Do not knock them, drop them or give an impact to them.
When disposing of them, removal of filled gas is required.
Contact us or our sales
service agent.
Continuing to operate with the accumulator remaining at
a low level of functions will result in failure. It cannot
relieve its residual pressure when the Machine is in
trouble.
Contact us or our sales service agency for the
replacement.
The accumulator is installed in the position indicated in
the sketch at the right.