345
5.2 MOMENT LIMITER FUNCTIONS
CAUTION
During the Fly-jib operations, always keep the boom angle in the range as specified below:
[At a Fly-jib angle in 0 or 20 degrees]
Perform the crane operation in the boom angle range of 45 degreesor more. When a load is
hoisted in a condition that the boom angle is less than 45 degreesand the boom length is
5.3 mor longer, the moment limiter emits a warning signal, the buzzer sounds intermittently,
and hook hoisting, boom telescoping and boom lowering operations automatically stop.
Such operations also automatically stop when it is beyond possible working range, and boom
angle lower limit light on the monitor blinks in red.
However, when the boom length is less than 5.3 m”, the moment limiter does not emit a
warning signal. In a condition where the boom angle is less than 45 degrees, boom lowering
operation is not available unless the boom length is less than 5.3 m”.
[At a Fly-jib angle in 40 or 60 degrees]
Perform the crane operation in the boom angle range of 65 degreesor more. When a load is
hoisted in a condition that the boom angle is less than 65 degreesand the boom length is
5.3 m” or longer, the moment limiter emits a warning signal, the buzzer sounds intermittently,
and hook hoisting, boom telescoping and boom lowering operations automatically stop.
Such operations also automatically stop when it is beyond possible working range, and boom
angle lower limit light on the monitor blinks in red.
However, when the boom length is less than 5.3 m”, the moment limiter does not emit a
warning signal. In a condition where the boom angle is less than 65 degrees, boom lowering
operation is not available unless the boom length is less than 5.3 m”.