CONTROL SYSTEM
07-40–18
*3
: Decreases to the manual voltage that is closest to the auto voltage.
*4
: Warm-up correction takes precedence.
*5
: Returns to condition prior to defroster operation. However, if it had been off prior to defroster operation, it
switches to automatic control.
*6
: MAX HOT and MAX COLD correction takes precedence.
*7
: Increases to the manual voltage that is closest to the defroster correction voltage.
*8
: Decreases to the manual voltage that is closest to the defroster correction voltage.
Airflow mode control, air intake control, A/C compressor control
*1
: Adjusted up or down in increments of 0.5 within a range of 15.0—32.0.
*2
: Returns to condition prior to defroster operation.
*3
: FRESH during HEAT, HEAT/DEF
*4
: A/C is set at ON during DEFROSTER, HEAT/DEF, HEAT. Switches only to the A/C display.
*5
: Set at FRESH during DEFROSTER, HEAT/DEF
*6
: A/C ON during HEAT, HEAT/DEF
Operation switch
Airflow mode control Air intake control A/C compressor control
Control prior to switch
operation
Control prior to switch
operation
Control prior to switch
operation
Automatic
control
Manual
control
Automatic
control
Manual
control
Automatic
control
Manual
control
OFF switch
Fixed at mode
before turned
OFF
No change
*2
FRESH No change OFF OFF
AUTO switch
Automatic
control
Automatic
control
Automatic
control
Automatic
control
Automatic
control
Automatic
control
Fan switch
+
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
-
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
MODE switch
VENT BI-
LEVEL
BI-LEVEL
HEAT
HEAT HEAT/
DEF
HEAT/DEF
VENT
DEFROSTER
HEAT
VENT BI-
LEVEL
BI-LEVEL
HEAT
HEAT HEAT/
DEF
HEAT/DEF
VENT
DEFROSTER
*2
Automatic
control
*3
No change
*3
Automatic
control
*6
No change
*6
DEFROSTER switch DEFROSTER
DEFROSTER
*2
Defroster
correction
Defroster
correction
*2
Defroster
correction
Defroster
correction
A/C switch
Automatic
control
No change
Automatic
control
No change
A/COFF
OFFA/C
*4
A/COFF
OFFA/C
*4
REC/FRESH switch
Automatic
control
No change
FRESHREC
RECFRESH
*5
FRESHREC
RECFRESH
*5
Automatic
control
No change
Driver-side
temperatur
e setting
dial
*1
15.0
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
15.5—31.5
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
32.0
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
Passenger
-side
temperatur
e setting
dial
*1
15.0
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
15.5—31.5
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
32.0
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
DUAL switch
Automatic
control
No change
Automatic
control
No change
Automatic
control
No change
3423-1U-06H(07-40).fm 18 ージ 20  