RIGHT HAND NON-RATCHETING
90-884294 OCTOBER 2001 Page 6A-69
6. Hand start two (2) fasteners into the water pump assembly and remove the water
pump locating pins. Install the remaining 2 fasteners. Run all fasteners down and
torque to 60 lb. in. (7 Nm).
7. Lightly lubricate the O-rings in the water tube coupling with 2-4-C Marine Lubricant
with Teflon.
8. Install the water tube coupling assembly to the water pump ensuring that the O-rings
are not damaged during assembly.
IMPORTANT: If seal installed above pump housing is not at the proper height, air
will be drawn into the pump resulting in overheating of the engine.
9. Using tool provided in seal kit (26-816575A2) or water pump kit (817275A3), press
seal down over drive shaft (DO NOT GREASE DRIVE SHAFT) until tool seats against
pump housing.
57945
a
b
a-Tool
b-Seal
If tool is not available, lightly press seal against housing until a height of 0.350 in. ± 0.030
in. (8.9mm ± 0.76mm) is obtained.
57946
0.350 in. ± 0.030 in.