5-12 MINI Hawk High Performance Imager User’s Manual
Serial Trigger
Serial Trigger
Serial Trigger Character (Delimited)
Note: Serial Data or Serial Data or External Edge triggering mode must be enabled for
Serial Trigger Character to take effect.
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K201h,3C>
For >: <K201h,3E>
For
, : <K201h,2C>
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
Usage: Allows the user to define the trigger character and delimiters that start
and stop the read cycle.
Definition: A serial trigger is considered an online host command and requires the
same command format as all host commands. It must be entered within
angle bracket delimiters < > or, in the case of non-delimited triggers, it must
define individual start and stop characters.
Usage: Allows the user to define the trigger character that initiates the read cycle.
Definition: A single ASCII host serial trigger character that initiates the read cycle.
A delimited trigger character is one that either starts or ends the read cycle
and is enclosed by delimiters such as < >.
Serial Cmd: <K201,serial trigger character>
Default: Space bar
Options: Any single ASCII character, including control characters, except NUL (00 in
hex), an existing host command character, or an on-line protocol character.
Control characters entered on the command line are displayed in the menu
as mnemonic characters.