MINI Hawk High Performance Imager User’s Manual 7-41
I/O Parameters
Quality Output
Separator
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K704h,3C>
For >: <K704h,3E>
For
, : <K704h,2C>
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
Decodes per Trigger Status
Definition: The separator character separates quality output data from symbol data.
Serial Cmd: <K704,separator,decodes per trigger status>
Default: ,
Options: Any ASCII character.
Definition: When this feature is enabled, the imager enters a state where it processes
frames as configured until the end of a read cycle, with or without a successful
symbol decode. When the read cycle ends, the imager outputs any
decoded symbol data along with the decodes per trigger count.
Serial Cmd: <K704,separator,decodes per trigger status>
Default: 0
Options: 0 = Disabled 1 = Enabled