3-20 MINI Hawk High Performance Imager User’s Manual
Response Timeout
Response Timeout
Note: See USB HID Interface on page 3-23 for protocol information relating to USB.
Usage: Only used when a response is required from the host. While in Multidrop, if
the imager does not receive an ACK or NAK from the host after sending
polled data, it will act on a fault. The reader can be set to wait indefinitely by
setting Response Timeout to zero.
Definition: The time that the imager will wait before timing out if ACK, NAK, and ETX
are enabled, and a host response is expected.
Serial Cmd: <K143,response timeout>
Default: 12 (in 1 ms increments)
Options: 0 to 255 (A zero (0) setting causes an indefinite wait.)