13-2 MINI Hawk High Performance Imager User’s Manual
Serial Utility Commands
Serial Utility Commands
Note: For a list of all K commands, see Serial Configuration Commands on page A-8.
Type Command Name
<C> Enter Decode Rate Test
Read Rate <Cp> Enter Percent Rate Test
<J> Exit Decode Rate and Percent Rate Test
<N> No Read Counter
<O> No Read Counter Reset
<T> Trigger Counter
Counter Request <U> Trigger Counter Reset
and Clear <V> Good Read/Match Counter
<W> Good Read/Match Counter Reset
<X> Mismatch Counter
<Y> Mismatch Counter Reset
<G> Store Next Symbol Read to Database Index 1
Master Database
<Gn> Store Next Symbol Read to Database Index n
<NEWM> New Master Load Status
<#> Display All Firmware Part Numbers
<#a> Display Application Code Part Number
<#b> Display Boot Code Part Number
Part Number / <#p> Display Profile Module Part Numbers
Checksum <!>
Display All Available Firmware Checksums
<!a> Display Application Code Code Checksum
<!b> Display Boot Code Checksum
<!p> Display Profile Module Checksum
<L1> Programmable Output 1
<L2> Programmable Output 2
<L3> Programmable Output 3
Device Control <l1> Targeting System On
<l0> Targeting System Off
<I> Disable Imager
<H> Enable Imager
<a1> Include PDF Information in Preamble (PDF417)
<A> Reset (does not save for power-on)
<Ard> Reset and Recall Microscan Defaults
Default/Reset/Save <Arp> Reset and Recall Power-On Parameters
<Arc>
Reset and Recall Customer Default Parameters
<Z> Save Current Settings for Power-On