MINI Hawk High Performance Imager User’s Manual 7-35
I/O Parameters
Service Message
When Service Message is enabled, a message of up to 10 ASCII characters is sent
whenever the system detects that the service timer’s limit has been reached. The service
timer is reset at power-on, meaning that the service timer’s limit is the amount of time
since last reset. Service timer increments can be set in seconds or minutes.
Service Message
Important:
The ASCII characters
<
,
>
, and
,
can only be entered as hex pairs:
For <: <K409h,,3C>
For >: <K409h,,3E>
For
, : <K409h,,2C>
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to
enter ASCII characters as hex values.
Threshold
Resolution
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 0
Options: 0 = Disabled 1 = Enabled
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: SERVICE
Options: An ASCII string between 1 and 10 characters.
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: 300 (5 minutes)
Options: 1 to 65535
Serial Cmd: <K409,status,service message,threshold,resolution>
Default: Seconds
Options: 0 = Seconds 1 = Minutes