14-10 MINI Hawk High Performance Imager User’s Manual
Output Filter Configuration
Filter Number
Symbology
Definition: This is the filter index number that represents the position of the symbol in the
data output at the end of the read cycle. This index number should be entered
along with the following filter settings for the predetermined symbol position.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
Options: 1 to 10
Definition: Specifies the symbology allowed to occupy this location in multisymbol output.
Note: To filter or order a symbol, the symbol must meet all the requirements
of the selected filter index.
Serial Cmd: <K744,filter number,symbology,length,wildcard,placeholder,data,
unused,database index>
Default: 0 (any symbology)
Options: 0 = Any type
1 = Interleaved 2 of 5
2 = Code 39
3 = Code 128
4 = Codabar
5 = UPC
6 = PDF417
7 = EAN 128
8 = Code 93
9 = Pharmacode
10 = GS1 DataBar (RSS)
11 = MicroPDF417
12 = Composite
13 = BC412
14 = Data Matrix
15 = QR Code
16 = Micro QR Code
17 = Aztec Code
18 = Postal Symbologies