EasyManua.ls Logo

Microscan MINI Hawk - Page 358

Microscan MINI Hawk
372 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-22 MINI Hawk High Performance Imager User’s Manual
Communications Protocol
Error Condition 2
Error Condition 3
The protocol makes 3 retry attempts before data is flushed and transfer is aborted.
HOST_TX RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data)
IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘LRC’
HOST_TX Nothing’ (Host should ‘ACK’ here)
timeout reached...
IMAGER_TX REQ’ (Unit requests an ‘ACK’ again)
HOST_TX NAK’ (Host rejects data frame)
(Retry Event)
IMAGER_TX 0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘LRC’ (Unit sends again)
HOST_TX ACK’ (Host receives data)
IMAGER_TX ‘RES’ (Terminate Transfer 1)
HOST_TX RES’ ‘0x1C’ ‘REQ’ (Poll Unit 1 for data)
IMAGER_TX ‘0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘BAD LRC’
HOST_TX ‘NAK’ (Host rejects bad LRC data)
(Retry Event)
IMAGER_TX 0x1C’ ‘STX’ <T/00000> ‘ETX’ ‘GOOD LRC’ (Unit sends again)
HOST_TX ACK’ (Host receives data)
IMAGER_TX RES’ Terminate Transfer 1)