9 PROGRAMMING
9.4 Communication Example Between the Master Station and Servo Amplifier
187
9
11. Set "PD01.0-7 Input signal automatic ON selection 1" to "00000C00".
12. Close the window by clicking "" in the upper right corner of the window, and click the [Yes] button.
13. Click the [Close with Reflecting the Setting] button to close the "CC-Link IE TSN Configuration" window.
14. Set the refresh settings as follows.
[Navigation window] [Parameter] [Module Information] [FX5-CCLGN-MS] [Basic Settings] [Refresh
Settings]
15. Click the [Apply] button.
16. Write the set parameters to the FX5 CPU module on the master station. Then, reset the FX5 CPU module or power off
and on the system.
[Online] [Write to PLC]
In this example, default values are used for parameters that are not shown above. For the parameters, refer to
the following.
Page 129 PARAMETER SETTINGS