22
4 FUNCTIONS
4.1 Function List
4 FUNCTIONS
4.1 Function List
The following tables list the functions of CC-Link IE TSN.
The symbols in the availability column mean as follows:
: Available, : Not available
Cyclic transmission
This function communicates data periodically among stations on the network using link devices.
Function Description Availability Reference
Master
station
Local
station
Communications using RX, RY, RWr, and
RWw
Communicates data in units of bits and words between the
master station and device stations.
Page 27
Communication
s using RX, RY,
RWr, and RWw
Link refresh Automatically transfers data between the link devices of the
FX5-CCLGN-MS and the devices of the FX5 CPU module.
Page 32 Link
refresh
Cyclic data assurance Assures the cyclic data integrity in units of 32 bits or station-
based units.
Page 34 Cyclic
data assurance
Communication cycle coexistence When device stations with different communication cycles are
included in the network, communicates data using multiple
communication cycles according to each device station.
Page 39
Communication
cycle
coexistence
I/O maintenance
settings
Output mode upon
CPU error
When a stop error occurs in the FX5 CPU module, set
whether to hold or clear output on the sending side.
Page 40 I/O
maintenance
settings
Output hold/clear
setting during CPU
STOP
When the status of the FX5 CPU module changes from RUN
to STOP, set whether to hold or clear output on the sending
side.
Data link faulty station
setting
Set whether to clear or hold input from a disconnected station.
Set it on the receiving side.
CANopen communications Controls a servo amplifier that supports the CANopen profile. Page 45
CANopen