Appendix 5 List of Link Special Register (SW)
279
A
SW00C8
to
SW00CF
Parameter setting status Stores the status of parameter settings.
0: No parameter setting
1: Parameter set
(Conditions)
Stations that surpass the maximum station number are ignored.

*1
SW00D0
to
SW00D7
Error invalid station setting
status
Stores the error invalid station setting status of each station.
0: Station other than an error invalid station
1: Error invalid station
(Conditions)
Stations that surpass the maximum station number are ignored.

*1
SW00E8
to
SW00EF
Station type match status Shows the match status of the parameters with the station types.
(This is available only for the number of connected modules.)
0: Station type matched
1: Station type mismatch

*1
SW00F0
to
SW00F7
CPU operating status of each
station
Stores the CPU operating status of each station.
0: RUN or PAUSE state
1: STOP state or moderate/major error
(Conditions)
Reserved stations and stations that surpass the maximum station
number are ignored.
Since a local station cannot obtain the station information of the
CC-Link IE TSN Class A remote station when communicating in
multicast mode, the CC-Link IE TSN Class A remote station
becomes the RUN or PAUSE state.

*1
SW0100
to
SW0107
CPU moderate/major error
status of each station
Stores the moderate/major error occurrence status of each station.
0: No moderate/major error
1: Moderate/major error occurring
(Conditions)
If an error occurs, data prior to error is held.
Reserved stations and stations that surpass the maximum station
number are ignored.
Since a local station cannot obtain the station information of the
CC-Link IE TSN Class A remote station when communicating in
multicast mode, "0: No moderate/major error" is reflected to the
CC-Link IE TSN Class A remote station.

*1
SW0110
to
SW0117
CPU minor error status of
each station
Stores the minor error occurrence status of each station.
0: Normal, or a moderate or serious error occurring
1: Minor error occurring
(Conditions)
Reserved stations and stations that surpass the maximum station
number are ignored.
Since a local station cannot obtain the station information of the
CC-Link IE TSN Class A remote station when communicating in
multicast mode, "0: Normal, or a moderate or serious error
occurring" is reflected to the CC-Link IE TSN Class A remote
station.

*1
SW0160
to
SW0167
Execution result of device
station parameter automatic
setting function
When the device station parameter automatic setting is completed
with an error, the bit of the target station is turned on.
On: Completed with an error
Off: Completed successfully
When the setting is completed with an error, the error code is stored
in 'Detailed execution result of device station parameter automatic
setting' (SW0194).
When completed with an error caused by the master station, the bit
is not turned on.

SW0194 Detailed execution result of
device station parameter
automatic setting
When the device station parameter automatic setting is completed
with an error, the error code is stored.
When completed with an error caused by the device station, the bit
of the target station of 'Execution result of device station parameter
automatic setting function' (SW0160 to SW0167) is turned on.

SW0198 Link dedicated instructions
processing result CH3
Stores the processing results of the link dedicated instruction that
used channel 3 of the own station.
0: Completed successfully
1 or greater: Completed with an error (Error code is stored.)
