4 FUNCTIONS
4.5 Security
55
4
Setting method
Set a remote password on the "Remote Password Setting" window.
[Navigation window] [Parameter] [Remote Password]
PING
This function uses the PING command to perform an alive check of external devices whose access is permitted in UDP
communications. When this function is used for UDP communications, check if the security setting of external devices (such
as a firewall) is set to respond to PING.
1. Click the [Password] button, and register the remote
password on the "Register Password" window.
[Password] button
2. Select the module for which the remote password is to
be applied, and set the "Intelligent Module No."
3. Set the target connection on the "Remote Password
Detail Setting" window.
"Detail Setting" for the target module
4. Write the remote password to the FX5 CPU module.
5. The remote password is enabled when the FX5 CPU
module is powered off and on or reset.