86
5 SYSTEM CONFIGURATION
5.2 Structure of CC-Link IE TSN Class B/A Devices (CC-Link IE TSN Protocol Version 2.0 Only) and Ethernet Devices
Connection with modules on CC-Link IE TSN with a communication speed of 100Mbps
This section describes the network topology when "Communication Speed" under "Application Settings" is set to "100Mbps".
Line topology
Adjust the communication speed of the module to 100Mbps to establish connections. (When connecting modules with
different communication speeds, an industrial switch is required.)
Star topology
The network is configured in a star topology via an industrial switch.
When the master station with a communication speed of 1Gbps and a local or remote station with a communication speed
of 100Mbps exist in the structure, set "Communication Period Setting" to "Low-Speed" for the local or remote station with a
communication speed of 100Mbps.
No.0: Master station
No.1: Local station
No.2, No.3: Remote station
No.0: Master station
No.1, No.2: Remote station
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
No.0
Class B (100Mbps)
No.1
Class B (100Mbps)
No.3
Class A (100Mbps)
No.2
Class B (100Mbps)
No.0
Class B (1Gbps)
No.1
Class A (100Mbps)
No.2
Class A (100Mbps)
No.0
Class B (1Gbps)
No.1
Class A (100Mbps)
No.2
Class A (100Mbps)
Industrial switch
(for CC-Link IE TSN Class A)
or
Industrial switch
(for CC-Link IE TSN Class B)
Low speed
Low speed
Industrial switch
(for CC-Link IE TSN Class A)
or
Industrial switch
(for CC-Link IE TSN Class B)
Low speed
Basic cycle

Table of Contents