5 SYSTEM CONFIGURATION
5.2 Structure of CC-Link IE TSN Class B/A Devices (CC-Link IE TSN Protocol Version 2.0 Only) and Ethernet Devices
89
5
If the communication speed of the master station is 1Gbps, the total cyclic data size of all device stations on the 100Mbps
device side at the boundary between communication speeds of 1Gbps and 100Mbps must not exceed 2K bytes.
No.0: Master station
No.1, No.2: Local station
No.3, No.4, No.5, No.6, No.7, No.8, and No.9: Remote station
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
Set the total cyclic data size within 2K bytes.
No.1
Class B (1Gbps)
No.4
Class B (1Gbps)
No.3
Class B (1Gbps)
No.8
Class B (100Mbps)
No.7
Class B (100Mbps)
No.9
Class A (100Mbps)
No.0
Class B (1Gbps)
No.5
Class A (100Mbps)
No.6
Class A (100Mbps)
Ò
Ò
No.2
Class B (1Gbps)
Industrial switch
(for CC-Link IE TSN Class B)
Industrial switch
(for CC-Link IE
TSN Class B)