1058
APPENDICES
Appendix 1 Operation Processing Time
Application
instruction
ANDTM>= When not executed 0.240 0.160 0.038
Comparison of
specified date
In
conductive
status
8.200 25.500 7.200 13.900 6.300 10.800
In non-
conductive
status
8.200 25.500 7.200 13.900 6.300 10.800
Comparison of
current date
In
conductive
status
6.500 23.100 5.900 12.500 5.100 9.500
In non-
conductive
status
6.500 23.100 5.900 12.500 5.100 9.500
ORTM>= When not executed 0.240 0.160 0.038
Comparison of
specified date
In
conductive
status
8.200 25.500 7.300 14.100 6.600 10.800
In non-
conductive
status
8.200 25.500 7.300 14.100 6.600 10.800
Comparison of
current date
In
conductive
status
6.500 23.100 6.000 12.700 5.300 9.500
In non-
conductive
status
6.500 23.100 6.000 12.700 5.300 9.500
SCL (S1) (S2)
(D)
SM750=
ON
Point No.1 < (S1) <
Point No.2
14.900 50.100 12.500 29.200 11.900 23.000
Point No.9 < (S1) <
Point No.10
15.800 50.900 13.200 29.100 12.100 23.000
SM750=
OFF
Point No.1 < (S1) <
Point No.2
13.900 53.100 12.100 28.900 10.900 22.200
Point No.9 < (S1) <
Point No.10
16.600 56.600 13.900 30.900 12.700 23.900
Category Instruction Condition (device) Processing time (s)
L02SCPU, L02SCPU-
P
L02CPU, L02CPU-P L06CPU, L06CPU-P,
L26CPU, L26CPU-P,
L26CPU-BT, L26CPU-
PBT
Min. Max. Min. Max. Min. Max.