7 APPLICATION INSTRUCTIONS
7.15 Clock Instructions
685
7
Writing clock data
DATEWR(P)
Processing details
Writes clock data stored in the device number designated by (S) or later device number to the clock element of the CPU
module.
Each item is set as a BIN value.
The "year" at (S) is designated by using four-digit year indication between 1980 to 2079.
(S)+1 designates the "month" in values of from 1 to 12 (January to December).
(S)+2 designates the "day" in values of from 1 to 31.
(S)+3 designates the "hour" in values of from 0 to 23 (using 24-hour clock, from 0 hours to 23 hundred hours). (Uses the
24-hour clock.)
(S)+4 designates the "minute" in values of from 0 to 59.
(S)+5 designates the "second" in values of from 0 to 59.
(S)+6 designates the "day of week" in values of from 0 to 6 (Sunday to Saturday).
Operation error
In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
(S): Head number of the devices where clock data to be written into the clock device is stored (BIN 16 bits)
Setting
data
Internal device R, ZR J\ U\G Zn Constant Others
Bit Word Bit Word
(S) 
Day of week Sun Mon Tue Wed Thu Fri Sat
Stored data 0123456
Error
code
Error details Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4100 The value outside the setting range has been set for each item. 
4101 The range of the device specified by (S) exceeds the range of the
corresponding device.

Basic
Process
High
performance
Redundant
Universal
LCPU
DATEWR
DATEWRP
Command
Command
DATEWR
DATEWRP
S
S
Year
Month
Day
+1
+2
+3
+4
+5
+6
Hour
Minute
Second
Day of week
Clock element
S
S
S
S
S
S
S